<LOGO>
FM Transmitter Measurement Report
Created: 2024-02-26 00-18-55
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
87.90 MHz 5/5, 42 dBuV R-VYSOC
Pilot RDS Phase Difference
0.0 kHz 3.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
5 kHz 6 kHz 18066 0,2380
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-5,1 dBr -1,80 dBr 0,3 dBr 0,1
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-VYSOC " 2D09 9 (Varied) 1 0 1 1 0:18, 26.02.2024
RT
"Cesky rozhlas Vysocina - zijeme tu s vami "
AF EON
87.9, 90.1, 96.5 MHz -
FM Scope Max at: 6 kHz MIN: 5 kHz % above 77 kHz: 0,2380 Acquired: 2024/02/26 0:18:52 Total samples: 18066 Equivalent time: 0:15:03 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600